+86 18068001229 01
Nā Transformers Pad-Mounted ʻEkolu-Phase 500kVA kiʻekiʻe-kūlana no ka ʻoihana
Nā Hiʻohiʻona Kūkulu
ʻO ke kumu
Nā ʻāpana kila silicon i ʻōwili anu ʻia: Ke komo ʻana o ke kahe koko kiʻekiʻe me ka insulation laminated e hōʻemi i ka pohō o ke au eddy.
ʻO ka hoʻolālā ʻelima-lālā ʻekolu-paepae: Hoʻemi i ka impedance zero-sequence a kāohi i nā harmonics.
ʻNā wili
ʻO ka wili uila kiʻekiʻe: ʻO ka pepa keleawe i wahī ʻia me ka pepa Nomex no ka pale ʻana i ke uila kiʻekiʻe.
ʻO ka wili uila haʻahaʻa: ʻAno cylindrical multi-layer no ka hoʻoikaika ʻana i ke kū'ē kaapuni pōkole.
ʻPahu a me ka hoʻoluʻu ʻana
Nā ʻēheu radiator corrugated: Hoʻoluʻu convection kūlohelohe me ka ʻole o nā mea pā o waho.
Hoʻolālā i hoʻopaʻa piha ʻia: Kāohi i ka hoʻoneʻe ʻaila a me ka haumia.
ʻʻŌnaehana Hoʻokaʻawale
ʻAila mineral (maʻamau) a i ʻole ʻaila ester FR3 (aloha i ke kaiapuni), e hāʻawi ana i ka pale ʻana, ka hoʻomaʻalili ʻana, a me ka hoʻopau ʻana i ke arc.
Pae hoʻokuʻu hapa ≤50pC (kūlike me IEC 60076).




Nā noi
Nā Pāka ʻOihana
Hoʻoikaika i nā mīkini kaumaha, nā laina hana (e like me nā mīkini paʻi, nā crane), a kākoʻo i nā ukana kaumaha pōkole.
ʻNā Hale Pāʻoihana
Hoʻolaha i ka mana no nā kukui, nā ʻōnaehana HVAC, nā elevators, a me ka palekana ma nā hale kūʻai nui, nā hōkele, a me nā keʻena.
Nā Papahana Hana Kūkulu
Nā kikowaena kaʻaahi, nā hale hana hoʻomaʻemaʻe wai ʻino, a me nā ʻōnaehana mana kahua mokulele.
ʻNā Hoʻonui ʻana o ka Pūnaewele Kuaʻāina
Hoʻololi i nā mea hoʻololi kahiko e hoʻomaikaʻi i ka hilinaʻi a me ka pono o ka ikehu.
Nā Pōmaikaʻi Koʻikoʻi
Hilinaʻi Kiʻekiʻe
Ua hala i nā hoʻokolohua kūpaʻa kaapuni pōkole IEC 60076, e hōʻoiaʻiʻo ana i ke kūpaʻa i ka wā o nā hewa grid.
Hoʻolōʻihi ka pahu i hoʻopaʻa piha ʻia i ke ola o ka ʻaila (me ka ʻole o ka mālama ʻana a hiki i 10 mau makahiki).
ʻKa Pono o ka Ikehu
Hoʻemi nā pohō ukana haʻahaʻa i nā kumukūʻai hana, e kūlike ana me nā kūlana IEEE C57.12.
ʻKa Hoʻololi ʻana i ke Kaiapuni
Hana i nā mahana koʻikoʻi (-40℃ a i +55℃) a me nā wahi kiʻekiʻe (≤3,000m).
Nā Koho Akamai
Kākoʻo i ka hoʻohui ʻana o ka IoT me nā mea ʻike mahana, nā mea nānā pae aila, a me nā ʻōuli mamao.
Hōʻoiaʻiʻo Kūlana
Hoʻomaʻamaʻa koʻikoʻi kēlā me kēia ʻāpana, me:
Nā hoʻāʻo pale ʻana i ka insulation a me nā hoʻāʻo uila impulse.
Nā ana o ka pohō ukana a me nā ana o ka pohō ukana ʻole.
Hōʻoia o ke kūpaʻa kaapuni pōkole.
Hōʻoia ʻia e ISO 9001, ISO 14001, a me KEMA no ka mālama honua.
Nā Alakaʻi Koho
Nā Koina Ukana
Ukana Hoʻomau: Koho i nā mea hoʻololi uila i helu ʻia he ≥125% o ka ukana kiʻekiʻe loa i manaʻo ʻia (e laʻa, 500kVA no ka hoʻohana mau ʻana he 400kVA).
Ke Kaumaha Pōkole: Pono paha nā noi ʻoihana i 150% o ka hiki ke kau no 30 mau minuke.
ʻNā Kūlana Kaiapuni
ʻŌpī wai/Paʻakai: Pono nā wahi kahakai i nā uhi pale i ka palaho.
Nā Pono o ka Wahi: E hōʻoia i kahi ākea he ≥1.5m a puni ka mea hoʻololi no ka mālama ʻana.
ʻHoʻokō
Kū i nā kūlana IEC 60076, IEEE C57.12, GB 1094 (Kina), a me ATEX no nā wahi weliweli.
ʻKoho ʻaila
ʻAila Mineral: Kūpono ke kumukūʻai no nā wahi maʻamau.
ʻAila Ester FR3: Kū i ke ahi a aloha i ke kaiapuni no nā wahi koʻikoʻi (e like me nā kikowaena ʻikepili).
Ke kau ʻana a me ka mālama ʻana
Ke kau ʻana
E hoʻohana i kahi kahua pālahalaha me ke kū'ē honua ≤4Ω.
Kākoʻo nā pilina uwea i nā uwea 185mm² (komo lalo a ʻaoʻao paha).
ʻMālama Maʻamau
Hapaha: E nānā i ka pae aila, ke kala, a me nā mea e liki ai.
I kēlā me kēia makahiki: E hoʻāʻo i ke kūpaʻa insulation (2,500V megohmmeter) a hana i ka nānā ʻana i ka chromatography aila.
Hoʻoponopono pilikia
Ka wela nui ʻana: E nānā i ka paʻa ʻana o ka radiator a i ʻole nā ukana kūpono ʻole.
Hoʻokuʻu hapa: E hoʻohana i ka chromatography aila e ʻike ai i nā hemahema insulation kūloko.



No ke aha e koho ai iā mākou
ʻO JIEZOU POWER, he mea hoʻolālā ʻoihana, mea hana a me ka mea hoʻokomo o ka ʻōnaehana mana ma ka honua holoʻokoʻa, ua hoʻokumu ʻia i ka makahiki 1989, nona kahi ʻāina he 200,000 mika kuea.
ʻO JIEZOU POWER, ka mea nui e hoʻokele i nā papahana pūnaewele mana, 500KV EPC, ka hale hana mana hydroelectric 230KV, ka hale hana mana 115KV, a pēlā aku.
Hiki i ka hale hana ʻo JIEZOU POWER ke hana i ka mea hoʻololi hoʻolaha ʻano aila a me ka maloʻo, ka mea hoʻololi mana max 500KV 480MVA, GIS, switchgear, substation, ma muli o ke kūlana ANSI/IEEE/DOE2016/CSA/IEC60076.
Ua loaʻa iā JIEZOU POWER ka palapala hōʻoia ISO9001, ISO14001, ISO45001, UL, CUL, CSA, SGS, TUV, INTERTEK, TYPE TEST REPORT. A hiki i ka makahiki 2023, ua hoʻolaha ʻia nā lālā a me nā hale hana ma ka honua holoʻokoʻa ma ʻAmelika Hui Pū ʻIa, Kanada, Dubai, Dominican Republic, Philippines, aia nā lālā a me nā ʻoihana Kina ma ke kūlanakauhale ʻo BengBu, ke kūlanakauhale ʻo FengYang, ke kūlanakauhale ʻo HaiAn, ke kūlanakauhale ʻo TaiZhou, ke kūlanakauhale ʻo SuZhou, ke kūlanakauhale ʻo ShenYang, a me ke kūlanakauhale ʻo FoShan.
I ka nānā ʻana i ka wā e hiki mai ana, ʻo ka hihiʻo o JIEZOU POWER ka lilo ʻana i mea hoʻolako hoʻonā ʻōnaehana mana hilinaʻi loa, e hoʻoponopono i nā pilikia hoʻokele mana koʻikoʻi loa o ka honua, e hoʻolalelale i ka hoʻololi ʻana o ka honua i ka ikehu hou. I hiki i nā mea a pau ke loaʻa kahi ola haʻahaʻa kalapona a mālamalama. No kēia hopena, e hana mākou i ka mea hiki loa e hoʻoikaika.



E nīnau i kēia manawa!
No nā nīnau e pili ana i kā mākou huahana a i ʻole ka papa inoa kumukūʻai, e ʻoluʻolu e waiho i kāu leka uila iā mākou a e hoʻopili mākou i loko o 24 mau hola.