Leave Your Message

Mea Hoʻololi Mana 138kv 132kv

Nā Loiloi Uila Mua: 132kV, 138kV a i ʻole nā ​​mea ʻē aʻe
Nā Loiloi Uila Lua: 11/10.5/6.6/6.3kV a i ʻole nā ​​mea ʻē aʻe
HV TAP RANGE: ±8 × 1.25% a i ʻole nā ​​mea ʻē aʻe
ʻANO PILI: YNd11 a i ʻole nā ​​mea ʻē aʻe
ʻANO: mea hoʻololi ʻaila i hoʻokomo ʻia

    Wehewehe Huahana

    Hoʻokumu ʻia ka Transformer 138 kV a me 132 kV ma ke Kūlana 1. GB 6451 Kikoʻī a me nā koi loea no nā mea hoʻololi mana i hoʻokomo ʻia i ka ʻaila; 2. IEC 60076 Power Transformers; 3. AS NZS 60076 Power Transformers; 4.CSAC88-16 Power Transformers; 5. ANSI/IEEE C57.12.00 IEEE Standard no nā Koina Laulā no ka Liquid-Immersed Distribution, Power, and Regulating Transformers; 6. GOST R 52719 Power Transformers - Nā Kikoʻī Laulā; 7. EN60076 Power Transformer; 8. Nā lawelawe ma hope o ke kūʻai kūloko ma ʻAmelika ʻĀkau ʻAmelika Hema a me nā wahi ʻē aʻe e pane i kāu mau pono i loko o 24 mau hola.
    hōʻoia
    Nā Palapala Hoʻololi 138 kV 132 kV
    Hoʻokō piha ka hoʻolālā a me ka hana ʻana o nā mea hoʻololi JZP 138KV 132KV i nā kūlana GB 6451, IEC 60076, AS NZS 60076, CSAC88-16, ANSI/IEEE C57.12.00, GOST R 52719, EN60076. ʻOi aku ma mua o 10 mau makahiki o ka ʻike hoʻolālā mea hoʻololi papahana honua o ka hui ʻenekinia ʻoihana o JZP. E like me kāu mau pono a me nā koi loea, hāʻawi iā ʻoe i ka hopena mea hoʻololi kūpono loa.
    Hoʻokumu ʻia ka mea hoʻololi 138 kV a me 132 kV ma ke ʻano maʻamau
    1. GB 6451 Nā kikoʻī a me nā koi loea no nā mea hoʻololi mana i hoʻokomo ʻia i ka ʻaila;
    2. Nā Mea Hoʻololi Mana IEC 60076;
    3. Nā Mea Hoʻololi Mana AS NZS 60076;
    4.CSAC88-16 Nā Mea Hoʻololi Mana;
    5. ANSI/IEEE C57.12.00 IEEE Standard no nā Koina Laulā no ka Hoʻolaha ʻana i loko o ka Wai, ka Mana, a me nā Transformers Hoʻoponopono;
    6. GOST R 52719 Nā Mea Hoʻololi Mana - Nā Kikoʻī Laulā;
    7. Mea Hoʻololi Mana EN60076;
    8. Nā lawelawe ma hope o ke kūʻai aku kūloko ma ʻAmelika ʻĀkau ʻO ʻAmelika Hema a me nā wahi ʻē aʻe e pane i kāu mau pono i loko o 24 mau hola.
    Pono e hoʻāʻo ʻia kēlā me kēia mea hoʻololi 132 kV a me 138kV o JZP e like me nā kūlana hoʻāʻo like ma mua o ka haʻalele ʻana i ka hale hana. Ma hope o ka hoʻokō piha ʻana o kēlā me kēia hoʻāʻo i nā koi like, hoʻouna ʻia i ka mea kūʻai aku e hōʻoia i kahi hōʻike hoʻāʻo mea hoʻololi. Hiki ke hoʻopaʻa ʻia a hoʻouna ʻia.
    Nā Kikoʻī o ka Mea Hoʻololi 138kV a me 132kV

    Mea hoʻololi mana OLTC ʻelua-pae ʻekolu 132kv

    Mana i helu ʻia

    Anakahi uila kiʻekiʻe

    Uila Haʻahaʻa

    ʻO ka pohō kaumaha ʻole (kw)

    Ka Pohō ma luna o ka ukana (kw)

    ʻAʻohe ukana i kēia manawa (%)

    10MVA

    132 kV

    6.3 kV

    11.8

    51.2

    0.82

    12MVA

    138 kV

    6.6 kV

    13.7

    59.5

    0.82

    15MVA

     

    10.5 kV

    16.3

    73.1

    0.76

    20MVA

     

    11 kV

    19.5

    88.4

    0.76

    25MVA

       

    22.7

    105

    0.69

    30MVA

       

    27.4

    126

    0.69

    37.5MVA

       

    32.9

    148

    0.63

    50MVA

       

    38.9

    184

    0.63

    60MVA

       

    46.4

    221

    0.57

    Mea hoʻololi mana NLTC papa ʻekolu-pae ʻelua wili 110kv

    Mana i helu ʻia

    Anakahi uila kiʻekiʻe

    Uila Haʻahaʻa

    ʻO ka pohō kaumaha ʻole (kw)

    Ka Pohō ma luna o ka ukana (kw)

    ʻAʻohe ukana i kēia manawa (%)

    10MVA

    132 kV

    6.3 kV

    11.8

    51.2

    0.64

    12MVA

    138 kV

    6.6 kV

    12.4

    59.5

    0.64

    15MVA

     

    10.5 kV

    15

    73.1

    0.59

    20MVA

     

    11 kV

    17.8

    88.4

    0.59

    25MVA

       

    21

    105

    0.54

    30MVA

       

    25

    126

    0.54

    37.5MVA

       

    29.9

    148

    0.56

    50MVA

       

    35.3

    178.5

    0.52

    60MVA

       

    41.9

    221

    0.48

    E nīnau i kēia manawa!