+86 18068001229 01
2000kVA ʻEkolu Pae Pad i kau ʻia ma luna o ka mea hoʻololi
Wehewehe Huahana
Hoʻokomo ʻia nā mea hoʻololi uila 2000kVA, 34.5kV o JZP Transformer i loko o kahi Pūnaehana Mālama Ikehu Battery (BESS) ma Kern County, Kaleponi, kahi e hāʻawi ai lākou i ka mana kōkua hilinaʻi e kākoʻo i nā lako like ʻole i loko o ke kahua mālama ikehu. Hoʻopau ʻia i Mei 2024 a hāʻawi ʻia i nā mea kūʻai aku ʻAmelika, he mea nui kēia mau mea hoʻololi uila no ka hōʻoia ʻana i ka hana hoʻopau ʻole a me ka hoʻokele mālama ikehu kūpono.
01020304050607
| Nā mahana ambient | ʻO ka palena iki -15.0°C, ʻO ka palena kiʻekiʻe he 41.0°C, ʻo ka awelika kiʻekiʻe loa no 24 hola he 33.0°C |
| Kiʻekiʻe | |
| Nā kūlana ōlaʻi: | Māhele Pōpilikia: II, Papa Kahua D |
| SS = 1.28 g, S1 = 0.43 g, SMS = 1.54 g, SM1 = 1.09 g, SDS = 1.03 g, SD1 = 0.73 g |
| Hana maʻamau (pae-a-pae) | 34.5kV |
| Hana kiʻekiʻe loa (pae-a-pae) | 38kV |
| Hoʻonohonoho wili | Delta |
| Ka helu ʻana o ka Bushing | 600A |
| Hoʻopaʻa wili | 200kV BIL |
| Hoʻopaʻa ʻana o ka pūʻulu | 200kV BIL |
| Ka nui o ka pūʻolo | ʻEono (Hoʻohānai Loop) |
| Kūpaʻa kaapuni pōkole | 30kA |
| Hoʻokaʻawale | Kuapo LBOR |
| Ka nui o ke kuapo e hoʻokaʻawale | Hoʻokahi (1) 3-Phase |
| Hana maʻamau (pae-a-pae) | 480V |
| Hoʻonohonoho wili | Wye Honua |
| ʻO ka wili a me ka insulation bushing BIL | KAʻA 30KV |
| Kūpaʻa i ke kaapuni pōkole | 65 kA* |
| Ka nui o ka lua ʻōpae LV bushing | (8) ʻAʻohe lua 2 |
| ʻO ka mea hoʻonui overvoltage maʻamau | 110% |
| Hoʻokumu ʻia ke kū'ē | ʻAʻole |
| Kaʻa ʻōhua honua | ʻAe |
| Ka uila hoʻolako kaapuni hoʻokele | 277V AC |
| Nā kikoʻī o ka mea haki kaapuni | Ua papa inoa ʻia ma UL |
| Kūpono no ke komo ʻana o ka lawelawe | ʻAe |
| Ana (i loko) | W*D*H: 83.9*94.7*95.3 |
| Pahu a me nā mea komo | 4,630 paona |
| ʻAila o ka nui | 900Gal |
| Kaumaha holoʻokoʻa | 21,600 paona |
Nā Hiʻohiʻona Koʻikoʻi a me nā Pōmaikaʻi
Ka Hoʻokaʻawale Mana Kūpono no ka Mālama ʻIkehu
Ua hoʻolālā ʻia nā mea hoʻololi uila 2000kVA e iho i lalo mai ka Medium Voltage (MV) a i ka Low Voltage (LV), e kūpono ai lākou no ka hoʻohui ʻana me nā papa kuapo i nā ʻōnaehana mālama ikehu. He mea nui kēia hoʻonohonoho stepdown no ka hōʻoia ʻana i ka hoʻokaʻawale ʻana o ka mana maʻalahi a hilinaʻi hoʻi i nā lako kōkua, e kākoʻo ana i ka pono holoʻokoʻa o ke kahua BESS.
Hoʻomaʻalili Hoʻomau a Kūpono ke Kumukūʻai
E like me ke kūpaʻa o JZP Transformer i ka hoʻomau ʻana, hoʻohana nā mea hoʻololi i ka ʻaila biodegradable ma ke ʻano he wai hoʻomaʻalili. ʻAʻole wale kēia hopena pili i ke kaiapuni e hāʻawi i nā waiwai insulation maikaʻi loa akā kākoʻo pū i ka pono o ka ikehu.
Paʻa a me ka Palekana i kūkulu ʻia
Nā Pā NEMA 3R: Aia kā mākou mau mea hoʻololi uila i loko o nā pā uila i helu ʻia e NEMA 3R i kū i ka ua, ka hau, a me ka hau, me nā pono hoʻokahe wai i kūkulu ʻia. Hāʻawi kēia mau pā i ka palekana ikaika mai nā mea, e pale ana i nā ʻāpana uila o loko a e hōʻoiaʻiʻo ana i ka lōʻihi o ka manawa ʻoiai ma nā kūlana kaiapuni ʻino.
Nā Hiʻohiʻona Anti-Tampering & Palekana: Hoʻolālā ʻia me ka noʻonoʻo ʻana i ka palekana, hōʻike nā mea hoʻololi i nā ʻano laka a me nā ʻano laka ʻē aʻe e pale aku i ke komo ʻae ʻole ʻia a me ka hoʻopunipuni ʻana, e hōʻemi ana i ka pilikia o ka ʻaihue a me ka hōʻoia ʻana i ka hana palekana i nā manawa āpau.
Hoʻolālā maʻalahi no ka palekana a me ka pono
ʻO ka ʻaoʻao haʻahaʻa o ka mea hoʻololi uila he hoʻolālā kūikawā i kau ʻia ma ka ʻaoʻao me kahi ʻāʻī no ka hoʻopili maʻalahi ʻana i ka papa kuapo. Aia nā ana i kau ʻia ma waho, nā kiwikā laʻana, a me nā ʻōnaehana hoʻokahe i loko o kahi keʻena laka me kahi laka bolt ʻelima-kiko. ʻAe kēia hoʻolālā kū hoʻokahi i nā mea hoʻohana e nānā palekana i nā pae aila, hoʻāʻo i nā ana, a hana i nā hana mālama me ka ʻole o ka hōʻike ʻana iā lākou iho i nā bushings voltage kiʻekiʻe (HV) a i ʻole nā mea haʻahaʻa voltage (LV), e hoʻonui nui ana i ka palekana a me ka pono hana.

Nā ana o waho o ka mea hoʻololi i kau ʻia ma luna o ka pad
Nānā Kiʻekiʻe a me nā Makaʻala Mamao
I mea e hōʻoia ai i ka hana mau a maikaʻi loa, ua lako ka mea hoʻololi me nā ʻōkuhi pae aila a me ka mahana e hōʻike ana i ʻelua mau wahi pili no ka nānā mamao ʻana. Hāʻawi kēia mau ʻōkuhi i ka ʻikepili manawa maoli i nā mea hoʻohana, e hoʻouna ana i nā hōʻailona hoʻāla ke kiʻekiʻe loa ka pae aila a haʻahaʻa loa paha. Eia kekahi, inā ʻoi aku ka mahana o ka wai coolant ma mua o 85°C, e hoʻāla ka ʻōnaehana i kahi hoʻāla. Inā piʻi ka mahana ma luna o 105°C, e hoʻokaʻawale koke ka mea hoʻololi mai ka pūnaewele e pale aku i ka wela nui a me ka hiki ke hōʻino ʻia, e hōʻoiaʻiʻo ana i ka palekana a me ka hilinaʻi o ka ʻōnaehana.

Ka maikaʻi a me ke kūlike
Hana ʻia nā mea hoʻololi JZP me ke kūlike pono me nā kūlana alakaʻi o ka ʻoihana, me UL, ANSI, IEEE, a me NEMA, e hōʻoiaʻiʻo ana i ka hana kiʻekiʻe, ka hilinaʻi, a me ka palekana. ʻO kā mākou kūpaʻa i ka maikaʻi a me ka hana hou e hōʻoiaʻiʻo ana ua kūkulu ʻia kēlā me kēia mea hoʻololi i nā kikoʻī kiʻekiʻe loa, e hāʻawi ana i ka lawelawe hilinaʻi ma ke ola holoʻokoʻa o nā lako.

E nīnau i kēia manawa!
No nā nīnau e pili ana i kā mākou huahana a i ʻole ka papa inoa kumukūʻai, e ʻoluʻolu e waiho i kāu leka uila iā mākou a e hoʻopili mākou i loko o 24 mau hola.