Leave Your Message

Mea Hoʻololi i kau ʻia ma luna o ka Pad 3-Phase 225 kVA 34.5kV

Nā Loiloi Uila Mua: 34.5kV
Nā Loiloi Uila Lua: 600/347V
ʻANO PILI: Dyn1
ʻANO: Ua kau ʻia ka pā
Nā Kūlana: CSA C227.4
Noi: Nā ʻōnaehana hoʻolaha ʻoihana
Ka helu mana: 225kVA
Palapala hōʻoia: CUL
ʻAno Hoʻoluʻolu: E noho mālie a aloha

    Wehewehe Huahana

    Ua haʻaheo ʻo JZP Transformer e hoʻolauna i ka mea hoʻololi pad-mounted 225 kVA 34.5kV 3-phase, i hoʻolālā kūikawā ʻia no nā ʻōnaehana hoʻolaha ʻoihana. Hana ʻia i nā kūlana kiʻekiʻe loa, hōʻoia ia i ka lako mana paʻa no nā ʻano hana ʻoihana like ʻole.
    palapala hōʻoia01
    palapala hōʻoia02
    palapala hōʻoia03
    palapala hōʻoia04
    palapala hōʻoia05
    palapala hōʻoia06
    palapala hōʻoia07
    palapala hōʻoia08
    palapala hōʻoia09
    01020304050607
    MEA HOʻOLOI I PAʻA ʻIA ME KA PAD ʻEKOLU

    Nā Kikoʻī ʻenehana o ka mea hoʻololi uila 225 kVA 34.5kV

    MANA I LOILOI ʻIA 225 kVA
    KA LOILOI KUMUWAIWAI 34500DELTA
    VOLTAGE KULA 600GrdY/347
    KA PINEPINE 60Hz
    Pūʻulu Vector Dyn1
    Mea Wili Alumini
    NALOWALE ʻANA O KA UME ≤2350W
    ʻAʻohe pohō kaumaha ≤650W
    UILA IMPEDANCE 5.75%
    KIʻEKIʻE ≤1,500m
    KALA ANSI 70 Hina māmā
    KAONA ʻAILA HOʻOMALU 1,040 L
    HUINA KAUmaha 2,300 kg
     

    225 kVA 34.5kV Mea Hoʻololi

    LUG HĀPAI ELSP FISE
    PUKA HINGED ʻO ka fiusi bayonet
    PAʻA KŪ NO KE KAʻA ʻANA HOʻOLOI PĪPĪ
    UHI PAHU ANA PAE ʻAILA
    LV BUSHING (4-HOLE) Kīwila Hoʻomaha Kaomi
    MEA HOʻOMĀLIE I KE KAOMI KA MEA HOʻOPIʻI HOLOHOLONA
    HV GROUNDING COPPER BAR POLOKALA KĪKINI
    HŌʻIKEʻIKE MAHANA PUKA PUKA
    Luawai ʻŌmole HV (35kV) Keleawe Kaula Honua
    ʻO ka lima keleawe hoʻoheheʻe honua PAPA INOA
    KUIHOʻO LOADBREAKE ʻELUA KŪLANA Nā Pā Kila Honua
    1"'DRAIN VALVE ME 3/8" SAMPLER Puka makani IR
    1" PILI KĀNANA PĀʻIMI VALVE PIHA I LUNA Pahu Kikowaena

    Nā Hiʻohiʻona Koʻikoʻi
    Puka makani IR (Puka makani infrared)
    Ua lako kēlā me kēia mea hoʻololi uila me nā puka makani IR ma nā keʻena voltage kiʻekiʻe a me nā keʻena voltage haʻahaʻa, e ʻae ana i nā mea hoʻohana e hana i nā scan thermal infrared me ka wehe ʻole ʻana i nā puka. Hōʻoia kēia hoʻolālā i nā nānā palekana a me ka pono, e hiki ai ke ʻike mua i nā wahi wela a i ʻole nā ​​​​pilikia wela. Ma ka ʻike ʻana i nā pilikia e like me ka overloading, nā pilina wehe, a i ʻole ka pilina maikaʻi ʻole, hoʻonui ka puka makani IR i ka paʻa o ka hana a me ka palekana o ka mea hoʻololi uila.

    Nā Mea Hoʻomalu Kiʻekiʻe
    Ua lako ka mea hoʻololi 225 kVA me nā ʻano hana palekana holomua e hōʻoia i ka palekana hana a me ke ola lawelawe lōʻihi, e like me:

    Mea Ana Kaomi Vacuum: Hoʻokomo pū ʻia me 2 mau pilina hoʻāla no ka nānā ʻana i ke kaomi manawa maoli, e hāʻawi ana i ka ʻōlelo aʻo mua o nā pilikia kūpono.

    Mea Hoʻomaha Kaomi: Me nā pilina pili, hoʻāla ia i kahi hōʻailona uila ke ʻike ʻia ke kaomi kūpono ʻole, e hoʻomaopopo ana i nā mea hoʻohana e hana i nā hana e pono ai.

    Hōʻailona Pae ʻAila: Loaʻa iā ia he 2 mau pilina hoʻāla e hoʻomaopopo i ka ʻōnaehana nānā ke kūpono ʻole ka pae ʻaila, e hiki ai i nā mea hoʻohana ke hoʻoponopono koke i ka pae ʻaila a mālama i ka hana palekana.

    Hōʻailona Mahana ʻAila: Aia i loko he 2 mau pilina hoʻāla—hoʻokahi no nā hōʻailona ʻōlelo aʻo a hoʻokahi no nā hōʻailona huakaʻi. Inā ʻoi aku ka mahana o ka ʻaila ma mua o 70°C, e hoʻopuka ka ʻōnaehana i kahi ʻōlelo aʻo; inā ʻoi aku ia ma mua o 105°C, e huakaʻi koke ka mea hoʻololi, a e hoʻouna ka ʻōnaehana nānā i kahi hōʻailona e hōʻike i ka hewa.

    Hoʻolālā maʻalahi no ka mea hoʻohana a me ka nānā ʻana i waho
    Nā Ana i Kau ʻia ma waho a me ka Drain & Sample Valve: Hiki i nā mea hana ke hoʻāʻo i ka ʻaila insulating a nānā i nā ana me ka ʻole o ka hōʻike ʻana iā lākou iho i nā bushings voltage kiʻekiʻe a me ka haʻahaʻa, e hoʻonui ana i ka palekana, ka pono, a me ka mālama ʻana.

    Palekana Palekana Mea Hoʻomaha Kaomi: Pale ka pale palekana i ka pōʻino o waho, ka hoʻāla ʻia ʻana, a me ke komo ʻana mai nā mea pili i ke kaiapuni, e hōʻoia ana i ka hana pono ʻana o ka mea hoʻomaha kaomi a me ka hōʻemi ʻana i ka pilikia o ka liki ʻana o ke kinoea. Pale pū ia i nā mea haumia mai ke komo ʻana i ka mea hoʻololi, e mālama ana i ka maʻemaʻe a me ke kūpaʻa lōʻihi.
    Nā Hiʻohiʻona Koʻikoʻi

    Ka Pono a me ka Hana Hou
    Ua hoʻolālā ʻia ka mea hoʻololi uila 225 kVA mai JZP Transformer me ka hoʻokūpaʻa ʻana i ka hilinaʻi lōʻihi a me ka palekana. Me nā puka makani infrared, nā ʻōnaehana nānā akamai, a me nā mana waho maʻalahi e hoʻohana ai, ʻaʻole wale ka mea hoʻololi uila e hoʻomaikaʻi i ka pono hana akā hoʻomaikaʻi pū i ka palekana o nā hana mālama. Kōkua kēia mau hiʻohiʻona i nā mea hana e ʻike a hoʻoponopono koke i nā pilikia hiki ke loaʻa, e hoʻemi ana i ka manawa downtime a me ka hōʻoia ʻana i ka hana mau.
    Ka Pono a me ka Hana Hou

    Nā noi hoʻololi 225 kVA
    Nā ʻōnaehana hoʻolaha mana ʻoihana
    Hoʻolako mana no nā ʻoihana a me nā hale noho
    Nā kikowaena hoʻololi mana a me ka ikehu hou
    Nā kikowaena ʻikepili a me nā ʻōnaehana koʻikoʻi
    Nā ukana mana koi nui
    Mea Hoʻololi JZP—Ke hōʻoiaʻiʻo nei i ka Mana Hilinaʻi no kāu mau Pono
    Ua kūpaʻa ʻo JZP Transformer i ka hāʻawi ʻana i nā hopena mana kiʻekiʻe i nā mea kūʻai aku ma ka honua holoʻokoʻa. Ma o ka ʻenehana holomua a me ka kaohi maikaʻi koʻikoʻi, hōʻoia mākou i ka lako mana paʻa a hilinaʻi hoʻi no nā papahana ʻoihana a me nā ʻoihana like ʻole. Inā he hoʻokomo lako, mālama, a hoʻolālā maʻamau paha, hāʻawi mākou i nā lawelawe ʻoihana a me ke kākoʻo.
    Nā noi hoʻololi 225 kVA

    E nīnau i kēia manawa!

    No nā nīnau e pili ana i kā mākou huahana a i ʻole ka papa inoa kumukūʻai, e ʻoluʻolu e waiho i kāu leka uila iā mākou a e hoʻopili mākou i loko o 24 mau hola.

    Leave Your Message