Leave Your Message

2500kVA ʻEkolu Pae Pad i kau ʻia ma luna o ka mea hoʻololi

Nā Loiloi Uila Mua: 34.5-19.92/13.8-7.957/13.2-7.62/12.47-7.2 a i ʻole nā ​​mea ʻē aʻe
Nā Loiloi Uila Lua: 208GrdY/120;416GrdY/240,480GrdY/277,/600GrdY/347,220y/127,480V,415v,600v a i ʻole nā ​​mea ʻē aʻe
HV TAP RANGE: ±2 × 2.5% a i ʻole nā ​​mea ʻē aʻe
ʻANO PILI: ʻO Dyn11/YNyn0 a i ʻole nā ​​mea ʻē aʻe
ʻANO: Ka hānai loop/ka hānai Radial
ʻO WAI: 30/150 kV
Nā Kūlana: IEEE, CSA, DOE
Noi: ʻO BESS, Crypto mining, ʻOihana, makani a me ka ikehu lā, hoʻouka EV
 Ka helu mana: 2500 kVA, 2550 kVA, 2.5 MVA
Palapala hōʻoia: UL, CUL, CSA, SGS

    Wehewehe Huahana

    He mea hana ʻoihana ʻo JZP Transformer o nā mea hoʻololi me nā papa inoa UL a me nā palapala hōʻoia no nā pae voltage a hiki i ka 44kV, e hāʻawi ana i kahi ākea o nā mea hoʻololi pad i hōʻoia ʻia e UL. I kēlā me kēia makahiki, hoʻokuʻu aku mākou i nā tausani o kēia mau mea hoʻololi i ʻAmelika Hui Pū ʻIa a me Kanada. Me ka ʻike ma IEEE/ANSI, CSA, DOE, NEMA, a me nā kūlana ʻē aʻe, hōʻoia kā mākou hui i ka hoʻokō ʻana me nā koi hoʻoponopono like ʻole. Ma waho aʻe o ka palapala hōʻoia UL, loaʻa iā mākou nā palapala hōʻoia CSA, MF, CESI, a me nā hōʻike hoʻāʻo SGS ʻaoʻao ʻekolu. Me ka ʻike nui o ka papahana, maopopo iā mākou he mau koi kūikawā kēlā me kēia papahana. ʻO ia ke kumu e hāʻawi aku ai mākou i nā mea hoʻololi i hiki ke hoʻopilikino ʻia, e ʻae ana i nā hoʻoponopono i ka voltage, ka mana, ke ʻano pili, a me ka hoʻolālā kūikawā e kūpono i kāu mau pono. Hiki ke hoʻopilikino ʻia ka mea hoʻololi pad 2500 kVA e kūpono i kāu mau koi papahana. E kelepona iā Daelim Transformer i kēia lā e loaʻa i ka pepa parameter, nā kiʻi, a me ka ʻōlelo no ka mea hoʻololi pad 2500 kVA.
    palapala hōʻoia01
    palapala hōʻoia02
    palapala hōʻoia03
    palapala hōʻoia04
    palapala hōʻoia05
    palapala hōʻoia06
    palapala hōʻoia07
    palapala hōʻoia08
    palapala hōʻoia09
    01020304050607

    Nā kikoʻī o ka mea hoʻololi 2500 kVA (2.5 MVA)

    Pae ʻEkolu pae Kūlana. Kūlana ANSI/IEEE C57 & DOE 2016 Kūlana
    Ka helu mana 2000kVA (2.5MVA) Hoʻonohonoho Ka hānai mua/loop make
    Ke kau ʻana Hoʻopaʻa ʻana i ka Pad Alapine (frequency) 60Hz
    Ka uila HV 13200/6720V Mea hoʻololi piula wai 5-kūlana
    Uila LV 600/347V Ka Mana Wai 1600L
    HE AHA KE KAʻA 95 kV Kaumaha holoʻokoʻa 7000kG
    KAʻA LV 30 kV ʻAʻohe pohō ukana 2500W
    Pūʻulu Vector I loko o 0 Ma ka nalowale o ke kaumaha 15000W
    ʻAno hoʻoluʻolu E noho mālie a aloha Palekana 5.75%
    Mea Wili Alumini Waihoʻoluʻu Pena ʻŌmaʻomaʻo ʻo Munsell
    Wai Hoʻokaʻawale ʻAila mea kanu palaho ʻole Ka piʻi ʻana o ka mahana ma 65 ℃ 2500 kVA
    ʻAno koʻikoʻi ʻEkolu pae ʻelima kolamu Ea Hoʻoikaika (Nā Pā) ʻAʻohe

    Nā hiʻohiʻona o ka mea hoʻololi 2500 kVA
    Nā hiʻohiʻona o ka mea hoʻololi 2500 kVA
    ʻO ka mea hoʻololi uila ZGSL-H-2500/13.2-0.6 e haʻaheo nei i kahi helu mana o 2500 kVA (2.5 MVA). ʻO ka mea hoʻololi uila 2500 kVA i kau ʻia ma luna o ka pad he helu uila mua o 13.2/7.62 kV me kahi pilina Wye, ka hoʻokumu ʻana o ka uila kiʻekiʻe H0, a me kahi uila lua o 600Y/347V Wye me ka hoʻokumu ʻana o ka uila haʻahaʻa H0.

    He mea maʻalahi ka mea hoʻololi uila ZGSL-H-2500/13.2-0.6 2500 kVA, a kūpono no ke kau ʻana i loko a me waho. Ua lako kēia mau mea hoʻololi uila me ka wai hoʻokaʻawale ʻaila mea kanu hiki ke palaho a mālama i ka piʻi ʻana o ka mahana 65°C. Hele mai lākou me 3 mau fuse ELSP a me 3 mau fuse bay-o-net no ka pale ʻana, me 3 mau bushings voltage kiʻekiʻe, 3 mau mea hopu kuʻekuʻe (HV), a me ʻehā mau bushings voltage haʻahaʻa, kēlā me kēia me 6 mau lua. Hoʻoikaika ʻia ke kūlana hoʻonohonoho terminal voltage haʻahaʻa me kahi pā Padmount. Eia kekahi, hōʻike ka mea hoʻololi uila 2500 kVA i kau ʻia ma luna o ka pad i kahi kuapo hoʻokaʻawale ukana ʻehā kūlana a me kahi mea hoʻololi tap ʻelima kūlana ma ka ʻaoʻao voltage kiʻekiʻe.

    ZGSL-H-2500/13.2-0.6
    ʻO ka ZGSL-H-2500/13.2-0.6 kahi mea hoʻololi pad-ʻekolu-paepae 2500 kVA me ka papa inoa UL. Hoʻopili ka mea hoʻololi pad 2500 kVA i ke kūlana IEEE C57.12.34 a ua kūlike me nā lula DOE. Hana ʻia me nā alakaʻi alumini a ua hoʻonohonoho ʻia e like me kahi mea hoʻololi ʻano loop-feed no nā ʻōnaehana dead-front. ʻO ke ʻano hoʻoluʻu i hoʻohana ʻia ʻo KNAN.

    ZGS-Z-2500(3050)/44/0.6
    ʻO ka ZGS-Z-2500(3050)/44/0.6 kahi mea hoʻololi kūikawā 2500 kVA ola-mua i kau ʻia ma luna o ka pad i hoʻolālā ʻia e hoʻokō i nā koi kūikawā o nā mea kūʻai aku Kanada e Daelim Transformer. Ua kūlike kēia mea hoʻololi 2500 kVA pad i kau ʻia me nā kūlana CSA C227.4 a me CAN/CSA 802.1. Loaʻa iā ia kahi uila kiʻekiʻe o 44 kV ma ke ʻano Delta a me kahi uila haʻahaʻa o 600GrdY/347V.

    Ua lako ka mea hoʻololi me ka ʻaila RAPO palaho ma ke ʻano he wai hoʻokaʻawale a ua hoʻolālā ʻia no ka piʻi ʻana o ka mahana o 55°C a i ʻole 75°C. ʻO kona helu kVA he 2500 kVA (2.5 MVA) ma ka piʻi ʻana o ka mahana 55°C a me 3050 kVA ma ka piʻi ʻana o ka mahana 75°C.

    ZGS-Z-2500(3050)/44/0.6
    ʻO ka mea e hoʻokaʻawale ai i kēia mea hoʻololi uila 2500 kVA, ʻo ia ka hoʻolālā ʻia ʻana o kona voltage haʻahaʻa e puka mai ka ʻaoʻao. Eia kekahi, ua kau ʻia nā anakahi, ka mea hoʻololi tap, ka papa inoa, ka valve hoʻomaha kaomi, a me ka valve hoʻopiha luna ma waho o ke keʻena mua. Ua lako kēia mau anakahi me nā pilina a ua hoʻopili ʻia i loko o kahi pahu mana waho NEMA 4. Aia kahi anakahi kaomi vacuum ma luna o ke keʻena mua. ʻO ka bushing voltage kiʻekiʻe he bushing porcelain i hoʻohui ʻia me ʻehā mau lua, a ua lako ka ʻaoʻao HV me ʻekolu mau mea hopu uila, e hāʻawi ana kēlā me kēia i kahi pāpale insulation e pale i nā kaula MV. Eia kekahi, ua hoʻokomo ʻia nā mea hoʻomehana anti-condensation i loko o ke keʻena mua voltage kiʻekiʻe no ka hana maikaʻi loa.
    2

    Mea Hoʻololi 2.5 MVA 3 PH
    ʻO ka ZGSL-Z-2500/44/4.16(2.4) he mea hoʻololi uila radial ʻekolu-paepa kūikawā 2.5 MVA. ʻO kona helu uila mua he 44,000 Delta V, ʻoiai ʻo ka uila lua he 4160Y/2400 V. Hoʻonohonoho ʻia ka mea hoʻololi uila me kahi hui pili uila kiʻekiʻe a haʻahaʻa DYn1, a kūlike ia me ke kūlana CSA C227.4. He 99.37% ka pono ikehu kupaianaha, e like me ke kūlana CAN/CSA-802.3. ʻO ka impedance o ka mea hoʻololi uila ma 85°C he 5.75%, a hāʻawi ia i ʻehiku pae o ka hoʻoponopono uila no ka ʻaoʻao uila kiʻekiʻe. Me ka mana aila insulating o 2000L a me ke kaumaha o 7500 kg, he ʻāpana lako nui ia.
    2

    Mea Hoʻololi 2.5 MVA
    ʻO ka mea nui, he hoʻolālā ia kahi e kau ʻia ai nā ʻāpana voltage kiʻekiʻe a me ka haʻahaʻa ma ka ʻaoʻao kau ʻana, me ka ʻāpana voltage kiʻekiʻe e hōʻike ana i kahi keʻena kikowaena ea i kau pono ʻia e hoʻolōʻihi ana i kona kumu. ʻO ka hoʻokomo ʻana o nā valves mea hana a me nā mea pono i hoʻonohonoho pono ʻia ma ka paia o ka pahu wahie waho e hoʻonui i ka hiki ke komo a hōʻoia i ka maʻalahi i hoʻohui ʻia, e hōʻike ana i ka hoʻolālā i hana ʻia me ka noʻonoʻo pono ʻia o ka mea hoʻololi.
    Mea Hoʻololi i kau ʻia ma luna o ka Pad 2550 kVA

    Mea Hoʻololi i kau ʻia ma luna o ka Pad 2550 kVA
    Hōʻike ka ZGSL-H-2550/34.5/0.415 i kahi mea hoʻololi paʻa ʻekolu-paepae loop-type pad-mounted, e kauoha ana i kahi helu mana kupaianaha o 2550 kVA. He ʻoi aku ka maikaʻi me ka mana voltage kiʻekiʻe o 34.5 kV me ka hāʻawi ʻana i kahi output voltage haʻahaʻa o 415Grd/240V. ʻO ka mea nui, ua hana pono ʻia kāna mau wili voltage kiʻekiʻe (HV) a me ka voltage haʻahaʻa (LV) mai ka alumini. ʻO kēia mea hoʻololi me ka helu pono o 99.4% a kūlike me ke kūlana IEEE Std C57.12.34. Eia kekahi, ʻo kona hoʻokomo ʻana i kahi kuapo hoʻokaʻawale ukana ʻehā kūlana e hoʻonui nui i ka hana a me nā ana palekana.
    Mea Hoʻololi 2550 kVA

    Mea Hoʻololi 2550 kVA
    Hoʻohana ka mea hoʻololi uila 2550 kVA i ka ʻōnaehana hoʻoluʻu ONAN/ONAF, a no laila, ua hoʻokomo pū ʻia me kahi hoʻonohonoho o nā peʻahi. Ke hana nei ma ke ʻano hoʻoluʻu ONAN, loaʻa i ka mea hoʻololi uila kahi helu mana o 2550 kVA. Eia nō naʻe, hiki i ke ʻano hoʻoluʻu ONAF ke lawelawe i kahi helu mana kiʻekiʻe o 3300 kVA. ʻO ka mea nui, ua lako ka mea hoʻololi uila me kahi ana wela aila me nā pilina alarm a ua hoʻopili ʻia i kahi keʻena hoʻokele kila kila 304 liʻiliʻi. ʻAe kēia hoʻonohonoho ʻana i ka nānā mamao ʻana i ke kūlana hana o ka mea hoʻololi uila.

    Aia ka moʻo ZGSL-H-2550/34.5/0.415 i ʻehā mau ʻāpana, i hoʻolālā kūikawā ʻia a hana ʻia no nā mea kūʻai aku ʻAmelika, a ua helu ʻia ʻo UL e hoʻokō i nā kūlana palekana a me ka maikaʻi paʻa.

    ZGSL-H-2550/12.47/0.415
    ʻO ka moʻo ZGSL-H-2550/12.47/0.415 he pūʻulu o nā mea hoʻololi 2550 kVA i hana ʻia e JZP Transformer no ka mea kūʻai aku ʻAmelika. ʻO kēia mau mea hoʻololi o ke ʻano pad-mounted a loaʻa iā lākou kahi hoʻonohonoho hānai loop. ʻO nā kikoʻī koʻikoʻi o kēia mau mea hoʻololi e komo pū me kahi kuapo hoʻokaʻawale ukana ʻehā kūlana, kahi mea hoʻololi tap ʻelima kūlana, nā ana me kahi hiʻohiʻona ʻaʻohe pā, ʻekolu mau fuse bay-o-net, a me ʻelua mau fuse palena o kēia manawa.
    12

    Mea Hoʻololi 12.47 kV 2550 kVA
    Ma ka ʻaoʻao haʻahaʻa-voltage, aia kahi bracket ma ka lālani e hāʻawi i ke kākoʻo no ke kikowaena. ʻO ka wai insulation i hoʻohana ʻia he aila mineral ASTM II, me ka mana o 440 galani. Ua hoʻolālā ʻia ka pahu e kū i kahi kaomi pahu maikaʻi loa o 10 PSI a me kahi kaomi pahu maikaʻi ʻole o 8 PSI. Mālama ʻia ka pae wai ma 10.0 ʻīniha mai ka piko o ka lua lima ma 25 ℃, me nā loli pae o 0.4 ʻīniha no 10 ℃. Ua hoʻolālā ʻia ka pahu no ka hoʻopiha ʻana i ka vacuum 7 PSI a ua helu ʻia no 2550 kVA i ka wā e hoʻoikaika ʻia ai ma 11,847 volts me ka mea hoʻololi tap ma ke kūlana 124,700-volt no kahi voltage lua o 415Y/240. ʻAʻohe pae PCB i ʻike ʻia i loko o kēia mau mea hoʻololi (emi ma mua o 2 ppm) i ka manawa o ka hana ʻana, e hōʻoiaʻiʻo ana i ka palekana o ke kaiapuni a me ka hoʻokō ʻana.
    13

    Mea Hoʻololi 13.2 kV 2550 kVA
    ʻO ka mea hoʻololi uila 2550 kVA kahi mea hoʻololi uila i hoʻolālā kūikawā ʻia e paʻa ana i kahi papa inoa UL, e hōʻoiaʻiʻo ana i kona kūlike me nā kūlana palekana a me ka maikaʻi koʻikoʻi. ʻO ka hui pili no kēia mea hoʻololi uila ʻo Dy1·Dd0, e hāʻawi ana i ʻelua mau ʻano pili like ʻole no ka voltage haʻahaʻa:

    No ka pilina 4160V Wye, aia nā kikowaena X1B, X2B, X3B no nā pilina pae, X1A, X2A, a me X3A no nā pilina kūlike ʻole. No ka pilina 2400V Delta, penei nā kikowaena: C1B a i X2A, X2B a i X3A, a me X3B a i X1A.
    24

    Mea Hoʻololi 24.94 kV 2550 kVA
    Ua kūkulu ʻia nā mea hoʻololi pad-mounted 2550 kVA a pau i loko o kēia moʻo e hoʻokō i ke kūlana IEEE C57.12.34, e hōʻoiaʻiʻo ana i ka maikaʻi a me ka hana kiʻekiʻe. Loaʻa iā lākou kahi hoʻolālā ʻāʻī ʻaoʻao-mau no ka pilina haʻahaʻa-voltage, e ʻae ana i ka hoʻohui maʻalahi me nā switchgear. Eia kekahi, ua hoʻolālā akamai ʻia ke kuapo hoʻokaʻawale ukana no kēia mau mea hoʻololi 2550 kVA i loko o ke keʻena haʻahaʻa-kaomi o ke keʻena mua, e hāʻawi ana i ʻehā mau kūlana no ka versatility. Hāʻawi ka mea hoʻololi tap i ʻelima mau kūlana, a ua hoʻonohonoho ʻia ke kāʻei hoʻoponopono kaomi ma 24.94 ± 2 × 2.5% no ka kaohi pololei. ʻO ka impedance o kēia mau mea hoʻololi ma 85 ° C he 5.87%, e hōʻoiaʻiʻo ana i ka hana paʻa a me ka pono. Eia kekahi, ua helu ʻia kā lākou mau pae insulation kumu kiʻekiʻe-voltage a me haʻahaʻa-voltage (BILs) ma 125kV a me 30kV, kēlā me kēia, e hōʻoia i ka hana insulation ikaika.

    E nīnau i kēia manawa!

    No nā nīnau e pili ana i kā mākou huahana a i ʻole ka papa inoa kumukūʻai, e ʻoluʻolu e waiho i kāu leka uila iā mākou a e hoʻopili mākou i loko o 24 mau hola.

    Leave Your Message