+86 18068001229 Ke Hoʻomaopopo ʻana i ke Kaomi, ke Kūʻē, a me nā Thermometers Fiber Optic
ʻO ka hana hilinaʻi o kahi Mea Hoʻololi ʻAila-Hoʻokomo ʻia hilinaʻi nui ia i ke kūpaʻa o kona ʻaila insulating kūloko a me nā mahana wili. ʻO ka hoʻomehana nui ʻana ke kumu nui o ka wikiwiki o ka ʻelemakule insulation, ka hōʻemi ʻana o ka hana, a ma ka hopena, nā hemahema. No laila, ʻo ka nānā ʻana i ka mahana kekahi o nā ʻano koʻikoʻi a koʻikoʻi o ka hana a me ka mālama ʻana i ka transformer. Mai nā dials mechanical kuʻuna a hiki i nā ʻōnaehana fiber optic akamai hou, ʻo ka mōʻaukala o ka hoʻomohala ʻana o ka thermometer he evolution o ka ʻenehana nānā transformer mai ka nānā passive a i ka ʻōlelo aʻo mua ikaika.
E hōʻike pono ana kēia ʻatikala i nā ʻano thermometer maʻamau i hoʻohana ʻia ma nā mea hoʻololi i hoʻokomo ʻia i ka ʻaila a hāʻawi i kahi loiloi hohonu o kā lākou mau loina hana a me nā hiʻohiʻona noi.
Mokuna 1: ʻO ka "ʻOhana Lāʻau" o nā Thermometers - He Nānā Kikoʻī i ʻEkolu ʻAno Nui
Ma muli o nā kumumanaʻo ana a me kahi hoʻokomo, ua māhele nui ʻia nā ana wela no nā mea hoʻololi i hoʻokomo ʻia i ka ʻaila i nā ʻano ʻekolu. I ka hui pū ʻana, hana lākou i kahi pūnaewele nānā ʻekolu-dimensional mai ka mahana o ka ʻaila kiʻekiʻe a hiki i nā wahi wela wili.
- Ana wela ʻano kaomi (Ana wela heluhelu mamao)
Kumu Hana: He mea hana mīkini maʻamau kēia e pili ana i ka hoʻonui ʻana/hoʻēmi ʻana o ka wela a me ka hoʻoili ʻana o ke kaomi wai/kinoea. Aia ka ʻōnaehana i ʻekolu ʻāpana:
ʻŌpuʻu Mahana (Sensor): Hoʻokomo ʻia i loko o ka ʻaila ma ka piko o ka pahu hoʻololi, i hoʻopiha ʻia me kahi mea pili i ka mahana (e laʻa, wai, kinoea, a wai paha e paila haʻahaʻa ana).
ʻO ka Paipu Capillary: He paipu metala lōʻihi a lahilahi e hoʻohui ana i ke kukui i ke poʻo ana, i hoʻopiha ʻia me kahi mea hoʻoili kaomi.
Poʻo Ana (Hōʻailona): Kau ʻia ma ka paia o ka pahu transformer a i ʻole ke keʻena hoʻomalu, hiki ke mika ka mamao mai ke kukui. ʻO kona kikowaena he paipu Bourdon - he paipu metala ʻōwili a elastic. Ke wela ka ipukukui, hoʻouna ʻia ka loli o ke kaomi kūloko ma o ke capillary i ka paipu Bourdon, e hoʻololi ai. Hoʻoneʻe kēia deformation i kahi pointer ma o kahi ʻano linkage, e hōʻike ana i ka mahana.
Nā ʻano koʻikoʻi:
ʻO ka mechanical maʻemaʻe, ʻaʻole pono ka mana o waho, palekana maikaʻi loa i ka hoʻopilikia electromagnetic, hilinaʻi kiʻekiʻe loa.
Hiki ke kau ʻia ke poʻo gauge ma kahi mamao no ka heluhelu kūloko maʻalahi.
ʻO ka maʻamau, ua hoʻolako ʻia me 1-2 mau pilina hoʻololi no ka hoʻāla wela a me nā hana hoʻokuʻi.
ʻOi aku ka lohi o ka pololei a me ka wikiwiki o ka pane ʻana i ka hoʻohālikelike ʻia me nā ʻano uila, a ua maʻalahi ka ʻōmole capillary i ka hōʻino mechanical.
Ka Hoʻohana Maʻamau: ʻO ka mea nānā mua a me ka mea hoʻāla no ka mahana o ka ʻaila kiʻekiʻe, kahi hiʻohiʻona kokoke i ke kūlana maʻamau ma nā mea hoʻololi ʻaila āpau.
- Mea ʻIke Mahana Kū'ē (RTD, e.g., PT100)
Kumu Hana: Ma muli o ke ʻano o ka loli ʻana o ke kūʻē ʻana o kahi alakaʻi me ka mahana. ʻO ka mea ʻike maʻamau ka ana wela kūʻē platinum, me PT100 e hōʻike ana i kahi kūʻē o 100 ohms ma 0°C. Hoʻololi pololei a linear kona kūʻē me ka mahana.
Nā ʻĀpana ʻōnaehana:
ʻŌmole RTD Platinum: Hoʻokomo ʻia i loko o kahi lua ana wela ma ka piko o ka mea hoʻololi, ua hoʻokomo ʻia i loko o ka ʻaila.
Ke Ana ʻana i ke Alahaka & ka Mea Hoʻoili: Hoʻohui pinepine ʻia i loko o kahi ʻāpana hoʻomalu akamai. Ana ke kaapuni pololei i ke kū'ē ʻana o ka PT100 a hoʻololi iā ia i kahi hōʻailona au maʻamau 4-20mA a i ʻole kahi hōʻailona kikohoʻe.
Nā ʻano koʻikoʻi:
ʻO ke ana pololei kiʻekiʻe, hiki ke hoʻouna ʻia nā hōʻailona ma nā mamao lōʻihi, ka palekana walaʻau maikaʻi.
He hōʻailona uila maʻamau ka hopena, i hoʻohui maʻalahi ʻia me nā kahua automation e like me SCADA (Supervisory Control and Data Acquisition) a me DCS (Distributed Control Systems) no ka nānā ʻana mamao kikowaena.
Hoʻokomo pinepine ʻia ma ka ʻaoʻao o ke ana wela ʻano kaomi, e lawelawe ana ma ke ʻano he mea hana hou a pololei paha no ka nānā mamao ʻana a me ka hoʻopaʻa ʻana i ka mahana o ka aila.
Ka Hoʻohana Maʻamau: Hoʻohana ʻia no ka hoʻoili mamao a me ka nānā ʻana kikohoʻe o ka mahana o ka ʻaila kiʻekiʻe, ke kihi o nā kikowaena hana ponoʻī hou, mālama ʻole ʻia.
- ʻŌnaehana Ana Mahana Winding Fiber Optic (Ke Ana ʻana "What-Spot" Pololei Kiʻekiʻe Loa)
Kumu Hana: ʻO kēia ka ʻenehana pololei a holomua loa no ka nānā ʻana i ka mahana o ka wili. Hoʻokumu ʻia ia ma ka physics o Fiber Bragg Gratings.
ʻIke Fiber Bragg Grating (FBG): Hoʻopaʻa ʻia kahi loli manawa i ka refractive index (he grating) i loko o kahi ʻāpana o ka fiber optical kūikawā me ka hoʻohana ʻana i ka laser. ʻO kona waiwai nui: Hoʻohuli ʻia ka mālamalama o kahi nalu kikoʻī (Bragg wavelength), a neʻe pololei kēia nalu i hōʻike ʻia me nā loli o ka mahana (a i ʻole ke kaumaha) ma kahi o ka grating.
Ke Kaʻina Hana Ana: Ua hoʻokomo mua ʻia kahi kaula fiber optic palupalu i hoʻokomo ʻia me nā mea ʻike FBG he nui ma waena o nā papa insulation o nā wili uila kiʻekiʻe ma nā wahi wela i wānana ʻia i ka wā o ka hana ʻana o ka mea hoʻololi. Hoʻopuka ka ʻōnaehana i ka mālamalama broadband, a ma ka nānā ʻana i ka nalu kikoʻī i hōʻike ʻia mai kēlā me kēia grating, hiki iā ia ke loaʻa pololei a i ka manawa maoli ka mahana piha ma nā wahi like ʻole i loko o ka wili.
Nā ʻano koʻikoʻi:
Ana pololei ʻana o ka mahana o ka wahi wela o ka wili, ʻaʻole ka manaʻo pololei ʻole. ʻO ka ʻikepili ka mea ʻoiaʻiʻo a hilinaʻi hoʻi.
Palekana maoli: Hana ʻia ka fiber optical i ka silica, insulating, kū i ke kiʻekiʻe o ka voltage, a palekana i ka hoʻopilikia electromagnetic, e hana paʻa ana i nā kahua EM ikaika.
Ana i hoʻolaha ʻia: Hiki i kahi fiber hoʻokahi ke hoʻokipa i nā ʻumi o nā wahi ʻike, e hiki ai ke hoʻolālā i kahi palapala wela piha o ka wili.
ʻO ke kumu hoʻoikaika koʻikoʻi no ka "Dynamic Rating" transformer a me ka loiloi ola holoʻokoʻa.
Hoʻohana Maʻamau: Nā mea hoʻololi nui a koʻikoʻi (e laʻa, EHV, nā mea hoʻololi mea hoʻololi), nā kikowaena akamai e koi ana i ka hoʻokele hiki ke ukana.
Mokuna 2: Ka Wehewehe ʻana i ke Manaʻo Koʻikoʻi - Ka Mahana ʻAila Luna vs. Ka Mahana Winding
He manaʻo koʻikoʻi kēia a me ke kumu hoʻomaka no ke koho ʻana i nā ʻano thermometer.
Mahana ʻAila Luna: Ke ana i ka mahana o ka ʻaila ma ka piko o ka pahu. Hōʻike ia i ka ukana wela holoʻokoʻa o ka mea hoʻololi akā he lohi wela. Ke loli ka ukana, loli koke ka mahana o ka wili, a ukali ʻia e ka mahana o ka ʻaila. Ke ana nā ana wela ʻano kaomi a me RTD i kēia.
Mahana Wela o ka Winding: Pili i ke kiko wela loa i ka mea hoʻololi holoʻokoʻa, aia ma ka ʻaoʻao kiʻekiʻe o ka wili haʻahaʻa voltage. ʻO ia ke ʻano koʻikoʻi loa e hoʻoholo ana i ka wikiwiki o ka ʻelemakule ʻana o ka insulation a me ka hiki ke ukana. ʻAʻole hiki i nā ʻano kuʻuna ke ana pololei iā ia, e hilinaʻi ana ma kahi Winding Temperature Indicator (WTI) e hoʻohālike/kuhi iā ia me ka hoʻohana ʻana i ka "top-oil temperature + current correction." ʻO ke ana ʻana o ka fiber optic wale nō ka ʻenehana e hiki ke ana pololei a pololei.