Hoʻolauna
Ua kapa pinepine ʻia ka ʻaila transformer ʻo ke "koko" o ka transformer. Hoʻokaʻawale ia, hoʻolulu, pale, a hōʻoia paha. No nā makahiki he ʻoi aku ma mua o hoʻokahi kenekulia, ʻo ka ʻaila mineral i loaʻa mai ka petroleum ka koho maʻamau. Akā, ʻo ka ulu ʻana o nā hopohopo kaiapuni a me nā koi palekana ahi ua hoʻokele i ka hoʻomohala ʻana o nā koho ʻē aʻe - ʻo ka mea nui loa, nā ʻaila ester kūlohelohe i loaʻa mai nā kumu mea kanu.
Hōʻike kēia ʻatikala i ka ulu ʻana o nā wai hoʻokaʻawale transformer a wehewehe i ke ʻano o kēia mau ʻokoʻa no nā poʻe loea kūʻai.
Māhele ʻEkahi: Nā Kūlana He Nui o ka ʻAila Transformer
Hoʻopaʻa ʻana.ʻO ke kuleana nui ka hoʻolako ʻana i ka insulation uila ma waena o nā ʻāpana ola. ʻO kona ikaika dielectric kiʻekiʻe e pale aku i nā kaapuni pōkole a me ka haki ʻana o ka uila.
Hoʻomaʻalili.Hoʻopuni ka ʻaila ma o nā wili a me ke kumu, e lawe ana i ka wela i nā radiators kahi e hoʻopuehu ai i ka lewa.
Ka hoʻopau ʻana i ke ʻākuhi.Inā loaʻa kahi hewa kūloko, kōkua ka ʻaila i ke kinai ʻana i ke arc hopena, e pale ana i nā pilikia liʻiliʻi mai ka hoʻonui ʻana.
Palekana.Hoʻokumu ka ʻaila i kahi pale ma waena o nā ʻāpana metala a me ka oxygen, e pale ana i ka pala.
Ka hōʻoia ʻana.Hana ka ʻaila ma ke ʻano he mea lawe ʻike. Ana ka loiloi kinoea i hoʻoheheʻe ʻia i nā kinoea i hana ʻia e nā ʻano hewa like ʻole, e hāʻawi ana i ka ʻōlelo aʻo mua o nā pilikia e ulu ana.
Māhele ʻElua: ʻAila Minerala—Ke Kūlana Kenekulia Kahiko
Hoʻomaʻemaʻe ʻia mai ka ʻaila maka, hāʻawi ka ʻaila mineral i ʻekolu mau pono nui: ka loaʻa ʻana ma ka honua holoʻokoʻa, ke kumukūʻai haʻahaʻa, a me ka ikaika dielectric maikaʻi loa.
Eia nō naʻe, he mau palena kona. He haʻahaʻa iki kona kiko ahi—ma kahi o 145°C a i 160°C—e hoʻoulu ana i ka pilikia ahi ma nā wahi i noho nui ʻia. Hoʻopōʻino mālie ia, maʻamau he 30 pakeneka wale nō, ʻo ia hoʻi, hiki i nā ninini ke hōʻino i ke kaiapuni i ka wā lōʻihi. A ma ke ʻano he huahana petroleum, ʻaʻole hiki ke hoʻohou hou ʻia.
Māhele ʻEkolu: Nā Esters Kūlohelohe—Ke Koho ʻŌmaʻomaʻo
Loaʻa mai ka soybean, rapeseed, a me nā aila mea kanu ʻē aʻe, ua kū mai nā esters kūlohelohe ma ke ʻano he koho alakaʻi.
Palekana Ahi.ʻOi aku ka nui o nā kiko lapalapa ma mua o 300°C—ʻoi aku ma mua o ka pālua o ka ʻaila mineral—e kūpono ana iā lākou no nā hoʻonohonoho kūlanakauhale a me loko.
Ka Hoʻohālikelike ʻana o ke Kaiapuni.He maʻalahi lākou e palaho a hiki ke hoʻemi ʻia he 97 pakeneka a ʻoi aku paha i loko o nā pule.
Ola Hoʻokaʻawale i Hoʻolōʻihi ʻia.Hiki i ka pepa i hoʻokomo ʻia i loko o ka ester kūlohelohe ke mau i 2.5 a 5 mau manawa ma mua o ka ʻaila mineral ma lalo o ke kaumaha wela like. Hoʻopili nā esters kūlohelohe i ka wai keu e hōʻino ai i ka pepa a hana i nā pilina pale me nā mole cellulose.
Ua hōʻoia nā haʻawina i kēia mau pono. Ma 100°C i nā wā lōʻihi, ua mālama ka ester kūlohelohe i ke kiʻekiʻe o ka volta breakdown ma mua o ka ʻaila mineral me ka hōʻike ʻana i ka ikaika tensile kiʻekiʻe a me ka resistivity paʻa.
Māhele ʻEhā: Ma ʻō aku o nā Esters Kūlohelohe—Nā Esters Hana ʻia a me nā ʻenehana e kū mai ana
No nā aniau anuanu loa a me nā papa voltage kiʻekiʻe loa, hāʻawi nā esters synthetic i ka paʻa oxidation i hoʻonui ʻia a me ka hana haʻahaʻa-mahana me ka mālama ʻana i nā pono o ke kaiapuni.
ʻO ka palena hou loa e pili ana i ka nanotechnology. Hiki i nā nanoparticles titanium dioxide ke hōʻemi i ka kiko ninini mai -5°C a i -32°C, e hiki ai ke hoʻohana i ke aniau anu. Hoʻomaikaʻi nā nanosheets boron nitride hexagonal i ka conductivity thermal a hiki i ka 40 pakeneka. Hoʻonui nā ʻāpana hui hao-keleawe i ka volta breakdown ma 32 pakeneka. Kuhikuhi kēia mau hoʻololi i kahi wā e hiki mai ana kahi e kūlike ai nā esters a ʻoi aku paha ma mua o ka aila mineral i kēlā me kēia māhele hana.
Māhele ʻElima: Nā Manaʻo Koho no nā Mea Kūʻai
Kaiapuni Noi.No nā wahi i loko, kūlanakauhale, a i ʻole nā wahi i pili i ke kaiapuni, hōʻoia nā esters kūlohelohe i kā lākou uku ma o ka palekana ahi a me ka hoʻemi ʻana i ke kuleana.
Ke aniau.ʻOi aku ka mānoanoa o nā esters kūlohelohe ma mua o ka ʻaila mineral, hiki ke hoʻopilikia i ka hoʻoluʻu ʻana i nā aniau anuanu. Ke hoʻohaiki nei nā ʻenehana additive i kēia āpau.
Kumukūʻai vs. Waiwai o ke Kaʻina Ola.ʻOi aku ke kumukūʻai o nā esters kūlohelohe i ka wā mua, akā ʻo ka lōʻihi o ke ola insulation hiki ke hōʻemi i ke kumukūʻai holoʻokoʻa no nā makahiki he ʻumi.
Ka Hoʻokō ʻana i nā Kūlana.Uhi ʻo IEC 60296 i ka ʻaila mineral; Uhi ʻo IEC 62770 i nā esters kūlohelohe. Pono nā mea kūʻai e hōʻoia i nā wai e kūlike me nā koi kūpono.
Hopena
Ua ulu aʻe ka ʻaila hoʻololi mai kahi huahana petroleum maʻalahi i loko o kahi wai ʻenekinia akamai. Hāʻawi nā esters kūlohelohe i kēia manawa i ka palekana ahi, ka hoʻohālikelike ʻana i ke kaiapuni, a me ke ola insulation i hoʻolōʻihi ʻia e hiki ʻole i ka ʻaila mineral ke hoʻokūkū. Hoʻokuke hou aku nā esters synthetic i nā palena hana. No nā poʻe loea kūʻai, he mea nui ka hoʻomaopopo ʻana i kēia mau koho no ka hoʻoholo ʻana i ka naʻauao.