Leave Your Message
Nā Māhele Nūhou
Nūhou i Hōʻike ʻia

Nūhou ʻOihana

Pehea e hoʻokaʻawale ʻia ai nā voltages kiʻekiʻe, waena, haʻahaʻa, a me Ultra-High i nā ʻōnaehana mana?

Pehea e hoʻokaʻawale ʻia ai nā voltages kiʻekiʻe, waena, haʻahaʻa, a me Ultra-High i nā ʻōnaehana mana?

2025-09-29

He mea nui ka hoʻokaʻawale ʻana o nā pae uila i loko o nā ʻōnaehana mana no ka hōʻoia ʻana i ka hoʻoili ikehu kūpono, ka hoʻolaha ʻana, a me ka palekana. Hoʻoholo nā pae uila pehea e lawe ʻia ai ka uila ma waena o nā pūnaewele, kaulike ʻia no ka hiki ke hana loea a me ka hoʻokele waiwai, a hoʻololi ʻia i nā noi like ʻole. Ke nānā nei kēia ʻatikala i nā pae hoʻohālikelike a me nā kūlana e hoʻomalu ana i kēia mau hoʻokaʻawale ʻana, me ka nānā ʻana i ​uila kiʻekiʻe (HV),uila waena (MV),uila haʻahaʻa (LV), a meuila kiʻekiʻe loa (UHV)ʻO ka hoʻokaʻawale ʻana o nā pae uila i nā ʻōnaehana mana he mea nui ia no ka hōʻoia ʻana i ka hoʻoili ikehu kūpono, ka hoʻolaha ʻana, a me ka palekana. Hoʻoholo nā pae uila pehea e lawe ʻia ai ka uila ma waena o nā pūnaewele, kaulike ʻia no ka hiki ke hana loea a me ka hoʻokele waiwai, a hoʻololi ʻia i nā noi like ʻole. Ke nānā nei kēia ʻatikala i nā pae a me nā kūlana e hoʻomalu ana i kēia mau hoʻokaʻawale ʻana, me ka nānā ʻana i ka ​uila kiʻekiʻe (HV),uila waena (MV),uila haʻahaʻa (LV), a meuila kiʻekiʻe loa (UHV).

nānā i nā kikoʻī
JZP Power Transformer: Ke hoʻoikaika nei i ka wā e hiki mai ana ma ENLIT Europe 2025

JZP Power Transformer: Ke hoʻoikaika nei i ka wā e hiki mai ana ma ENLIT Europe 2025

2025-09-24

Ma ke ʻano he mea hana alakaʻi i loea i nā mea hoʻololi uila waena a me ke kiʻekiʻe, hauʻoli ʻo JZP Power Transformer e hoʻolaha i ko mākou komo ʻana i ka ENLIT Europe 2025—ka hanana koʻikoʻi o ka ʻāina no ka hana hou ʻana i ka ikehu. Mai Nowemapa 18-20, 2025, e hōʻike mākou i kā mākou mau hoʻonā ʻoi loa ma ke kikowaena hōʻikeʻike ʻo Bilbao (48100 Bilbao, Bizkaia, Sepania). E kipa mai iā mākou ma Booth 3.F122 e ʻike pehea mākou e hoʻohālikelike nei i ka wā e hiki mai ana o ka hoʻoili a me ka hāʻawi ʻana i ka mana.

nānā i nā kikoʻī
E hui pū me mākou ma ka 2025 3E XPO!

E hui pū me mākou ma ka 2025 3E XPO!

2025-09-24

Ma ke ʻano ikaika o ke kahua ikehu honua, kū ʻo JZP ma ke ʻano he mana paionia i loea i nā mea hoʻololi uila waena a me ke kiʻekiʻe—ke kuamoʻo o ka hoʻoili mana kūpono, ka hoʻolaha ʻana, a me ka hoʻohana ʻana. Me nā makahiki he ʻumi o ka ʻike loea, ka ʻenehana holomua, a me ka kūpaʻa paʻa ʻole i ka maikaʻi, hoʻoikaika mākou i nā ʻoihana, nā pono hana, a me nā papahana ma ka honua holoʻokoʻa e hoʻokō i nā hopena ikehu hilinaʻi, hoʻomau, a me ke kumukūʻai kūpono.

 

nānā i nā kikoʻī
Nā Mea Hoʻololi Uila Waena a me ke Kiʻekiʻe: He Alakaʻi ʻenehana

Nā Mea Hoʻololi Uila Waena a me ke Kiʻekiʻe: He Alakaʻi ʻenehana

2025-09-23

Hana ʻo Switchgear ma ke ʻano he iwi kuamoʻo o nā ʻōnaehana mana voltage waena a me ke kiʻekiʻe (MV/HV), e hana ana i ʻekolu mau kuleana koʻikoʻi no nā mea hoʻololi:

  • ʻKa Hoʻokaʻawale Mana: Hoʻokele i ka uila mai nā mea hoʻololi uila i nā ukana ma o nā mea hānai, nā busbars, a me nā mea pale.
  • ʻPalekana Hapa: Hoʻopau i nā kahe hewa i loko o nā milliseconds (e laʻa, 31.5kA–40kA ka mana haki pōkole) e pale aku i ka hōʻino ʻia o nā lako.
  • ʻHoʻokaʻawale Palekana: Hōʻoia i ka mālama palekana ma o nā laka mechanical a me nā mīkini hoʻoheheʻe honua.

Eia kekahi laʻana, koi kahi ʻōnaehana 12kV i ka liʻiliʻi loa o ka ʻae ʻana mai ka pae a i ka honua he 125mm (insulated air) a i ʻole 40mm (insulated gas) e pale aku i ka arcing.

.

nānā i nā kikoʻī
Ka Nānā Kikoʻī o nā ʻAno Hoʻololi Uila Mana Mana M&H Voltage, nā Hoʻonohonoho Kūkulu, a me nā Palena Koʻikoʻi

Ka Nānā Kikoʻī o nā ʻAno Hoʻololi Uila Mana Mana M&H Voltage, nā Hoʻonohonoho Kūkulu, a me nā Palena Koʻikoʻi

2025-09-22

ʻKa Nānā Kikoʻī o nā ʻAno Transformer Mana Uila Mana M&H Voltage, nā Hoʻonohonoho Kūkulu, a me nā Palena Koʻikoʻi

nānā i nā kikoʻī
Loiloi ma luna o Topology a me nā noi hoʻomalu o nā Transformers uila mana uila waena-kiʻekiʻe III

Loiloi ma luna o Topology a me nā noi hoʻomalu o nā Transformers uila mana uila waena-kiʻekiʻe III

2025-09-18

Hōʻike ʻia ka topology multilevel Neutral Point Clamped (NPC). Ma waho aʻe o ka topology NPC diode-clamped, hoʻokomo pū nā topology NPC i ke ʻano capacitor lele a me ke ʻano hybrid clamped, a me nā mea ʻē aʻe. Eia nō naʻe, ma muli o ka nui o ka capacitor, hoʻohana nui nā topology NPC i nā mea hoʻololi passive a active paha no ka clamping. Ke lawe nei i ka topology multilevel diode-clamped ma ke ʻano he laʻana, i loko o kahi topology pae rectifier ʻekolu-phase, ʻo kēlā me kēia wāwae phase e loaʻa ana nā transistors hoʻololi cascaded a me nā diodes clamping, i hoʻopili ʻia ma ke ʻano like me kahi kaʻa DC kiʻekiʻe-voltage hoʻokahi. Ua hāpai ka palapala i kahi topology PET hoʻokahi-phase me kahi kahua rectifier e hoʻohana ana i kahi kaapuni diode-clamped ʻehā-pae. Ua ukali ʻia kahi kaʻa DC kiʻekiʻe-voltage hoʻokahi e nā DAB input-series-output-parallel, e like me ka mea i hōʻike ʻia. Hiki ke hoʻonui ʻia kēia topology i loko o kahi ʻano ʻekolu-phase, a hiki ke hoʻololi ʻia ka helu o nā pae voltage ma muli o nā pae voltage e kū nei i ka hāmeʻa a me ka pae voltage ʻaoʻao kiʻekiʻe-voltage. E like me ka topology MMC, hiki ke hoʻopili ʻia ka topology NPC i ke kahua hoʻokaʻawale, e hoʻopili ana i ke kaʻa DC voltage kiʻekiʻe i ka mea hoʻololi hoʻokaʻawale, e like me ka mea i hōʻike ʻia. Ua hoʻopili ka palapala i kahi mea hoʻololi NPC diode-clamped ʻekolu-pae i ka ʻaoʻao voltage kiʻekiʻe o kahi mea hoʻololi resonant LLC, e hōʻoia ana iā ia ma kahi prototype 166kW/2kV ~ 400V. Ua hoʻopili ka palapala i kahi kaapuni NPC diode-clamped ʻekolu-pae i kahi DAB ʻekolu-pae, e hoʻokō ana i nā ʻano voltage DAB kūpono a me kēia manawa.

nānā i nā kikoʻī
Loiloi ma luna o ka Topology a me nā noi hoʻomalu o nā mea hoʻololi uila mana uila waena-kiʻekiʻe II

Loiloi ma luna o ka Topology a me nā noi hoʻomalu o nā mea hoʻololi uila mana uila waena-kiʻekiʻe II

2025-09-18

ʻOkoʻa loa nā topologies PET. Ma muli o ka helu o nā pae hoʻololi ikehu, hiki ke hoʻokaʻawale ʻia i nā ʻano pae hoʻokahi, pae ʻelua, a me nā ʻano pae ʻekolu [7]. ʻO nā ʻano pae ʻelua e komo pū me nā kaʻa DC voltage kiʻekiʻe a me ka voltage haʻahaʻa, e like me ka mea i hōʻike ʻia ma ke Kiʻi 1.

nānā i nā kikoʻī
Loiloi ma luna o Topology a me nā noi hoʻomalu o nā mea hoʻololi uila mana uila waena-kiʻekiʻe I

Loiloi ma luna o Topology a me nā noi hoʻomalu o nā mea hoʻololi uila mana uila waena-kiʻekiʻe I

2025-09-16

Me ka manaʻo o ka manaʻo pūnaewele ikehu a me ka hoʻohana nui ʻana o nā ʻenehana pili i ka pūnaewele akamai, e piʻi nui ka hapa o nā kumu ikehu hou e like me ka makani a me ka mana photovoltaic i loko o ka ʻōnaehana ikehu e kū nei. Hōʻike kēia e lilo nā pūnaewele mana e hiki mai ana i mea akamai a maʻalahi hoʻi. Ma ka pūnaewele ikehu, i ka piʻi ʻana o ka hapa o nā mea hoʻohana i hoʻolaha ʻia a me nā kumuwaiwai ikehu, koi ka hoʻoili uila i nā hiki ke hoʻomalu nui ʻia. Ma nā pūnaewele hoʻolaha akamai, pono ka pūnaewele e mālama i ka lako mana paʻa a kiʻekiʻe me ka hoʻohui ʻana i kahi nui o nā kumu ikehu hou i hoʻolaha ʻia a me ka nānā ʻana/hoʻokele ʻana i nā kūlana hana o ka pūnaewele. Hoʻokau kēia mau koi i nā koi koʻikoʻi ma ka naʻauao o nā lako pūnaewele ikehu, ʻoiai ʻo nā mea hoʻololi alapine mana kuʻuna e kū nei i nā palena hana.

nānā i nā kikoʻī
Mea Hoʻololi Uila Kiʻekiʻe: Wehewehena, Nā Kumu Hana, a me nā Noi

Mea Hoʻololi Uila Kiʻekiʻe: Wehewehena, Nā Kumu Hana, a me nā Noi

2025-09-15

ʻO ka mea hoʻololi uila kiʻekiʻe he mea uila i hana ʻia e hoʻololi i ka ikehu uila ma waena o nā pae uila, e hana pinepine ana i loko o ka pae o110 kV a i 500 kVHe mea koʻikoʻi kēia mau mea hoʻololi uila i nā ʻōnaehana hoʻoili mana, e hoʻemi ana i ka nalowale o ka ikehu i ka wā o ka hoʻoili ʻana ma kahi mamao loa me ka hōʻoia ʻana i ka lawe palekana ʻana o ka uila i nā hale, nā ʻoihana, a me nā ʻoihana. No ka laʻana, hoʻopuka nā mea kanu mana i ka uila ma nā voltages kiʻekiʻe, a hoʻoponopono nā mea hoʻololi uila i kēia voltage—e hoʻokiʻekiʻe ana no ka hoʻoili ʻana a i ʻole e hoʻohaʻahaʻa ana no ka hoʻohana ʻana o ka mea hoʻohana hope—e hoʻonui i ka pono a me ka palekana.

.

nānā i nā kikoʻī
Hoʻonā ʻōnaehana photovoltaic solar

Hoʻonā ʻōnaehana photovoltaic solar

2025-09-12

He alakaʻi honua ʻo JZP Transformer i ka lawelawe ʻana i ka ʻoihana ikehu hou ma ka honua holoʻokoʻa. Me kahi moʻolelo i hōʻoia ʻia, ua hoʻolako mākou i nā tausani o nā mea hoʻololi no nā papahana photovoltaic a me ka mālama ikehu ma ʻAmelika ʻĀkau, ʻEulopa, a me Australia. ʻAʻole wale kā mākou huahana e hoʻokō i nā kūlana koʻikoʻi e like me IEEE, ANSI, CSA, AN, IEC, a me BS, akā loaʻa pū kekahi mau palapala hōʻoia e like me UL, cUL, CSA, CE, SGS, a me nā mea ʻē aʻe, i kākoʻo ʻia e nā hōʻike hoʻāʻo piha.

nānā i nā kikoʻī